Endüstriyel Tesis | RMP Validation Exercise Plant [Validation], Italy |
---|---|
Tür | Storage Tank |
Kod | U14 |
Madde | Ethylene oxide (75-21-8) |
Tank height from the ground | 0 m |
Volume | 6.0465 m3 |
Surface Roughness | 700 mm (0.7 m) |
Obstruction Class | Obstructed |
Status | Operational |
Shell Density | 7800 kg/m3 |
Base Type | On-ground |
Base Support Type | Anchored |
Construction Material | Steel |
Storage Volume | 6.0465 m3 |
Storage Capacity | 5336.4 kg |
Storage Condition | Pressure |
Storage Temperature | 25°C |
Storage Pressure | 1.7284 atm |
Gauge Pressure | 0.7284 atm |
Storage State | Liquid |
Fill Percent | 85 %v |
Stored Volume | 5.1395 m3 |
Stored Quantity | 10000 lb (4535.9 kg) |
Passive Release Mitigation Factor | 1 |
Active Release Mitigation Factor | 1 |
Notlar | See U.S. EPA (1999), Example 14 (Chapter 4, page 4-6). |
Erişim | Genel |
No | Afet Türü | Ad | Tarih | Tesis # | ||
---|---|---|---|---|---|---|
1. | Earthquake | RMP Validation Exercise, Example 14 [Validation] | 28/04/2017 12:51:03 | 1 | Serkan GIRGIN |
Risk Değerlendirmesi | Doğal Afetler | Endüstriyel Tesisler | Bilimsel | Kullanıcılar |