Damage Classification

NameDi Carluccio et al. (2006) - Pressurized Equipment
Hazard TypeEarthquake
Plant Unit TypeStorage Tank
Description

Damage states for pressurized tanks according to Di Carluccio et al. (2006).

States
NoCodeNameDescription
1.DS1None

Null damage (no loss of containment).

2.DS2Minor

Small cracks or failures (leakage).

3.DS3Major

Big cracks or failure of auxiliary system (catastrophic loss of containment).

ReferencesA. Di Carluccio, I. Iervolino, G. Manfredi, G. Fabbrocino, E. Salzano, "Quantitative probabilistic seismic risk analysis of storage facilities", 2006
AccessPublic
Created: Serkan GIRGIN, 2017/04/18 13:00:42

Fragility Curves

NoNameParameterUnitValidity Conditions
1.Di Carluccio et al. (2006), Pressurized EquipmentPGAgBase Type: Above Ground; Storage Condition: Pressurelog μ̃2-