Classification des dommages

NomSeligson et al. (1996) - Pump
Type de risqueEarthquake
Type d'unité d'installation industriellePump
Description

Damage states for feed controller units (pumps).

Etats
NoCodeNomDescription
1.DS1None

None or insignificant structural damage (damage ratio: 0 - 0.05%).

2.DS2Light

Possible movement of equipment; no damage to piping (damage ratio: 0.05 - 1.25%).

3.DS3Moderate

Failure of some connected piping; equipment displacement with some internal damage; moderate chance of realease of reactants (damage ratio: 1.25 - 20%).

4.DS4Severe

Failure of most piping connections; equipment damaged; almost certain release of reactants (damage ratio: 20 - 65%).

5.DS5Total

Failure of all piping connections; equipment damaged; reactants released (damage ratio: 65 - 100%).

RéférencesSeligson, H. A.; Eguchi, R. T.; Tierney, K. J.; Richmond, K., "Chemical hazards, mitigation and preparedness in areas of high seismic risk: a methodology for estimating the risk of post-earthquake hazardous materials release", 1996
AccèsPublic
Créé: Vincenzo ARCIDIACONO, 31/01/2014 15:03:07 – Mis à jour: Serkan GIRGIN, 01/03/2016 14:23:00

Courbes de fragilité

NoNomParamètreUnitéConditions de validité
1.Seligson et al. (1996)MMI--5-

Évaluation des risques

Risques naturels

Installations industrielles

Scientifique

Utilisateurs