Référence

TypeReport
TitreMethods for the Calculation of the Physical Effects of the Escape of Dangerous Material (Liquids and Gases)
AuteursTNO
Année1980
InstitutionTNO Bureau for Industrial Safety
ÉditeurNetherlands Organization for Applied Scientific Research
AccèsPublic
Créé: Serkan GIRGIN, 19/11/2012 14:28:06

Estimateurs de propriété

NoNomPropriétéValeurConditions de validité
1.Characteristic wind speed for pool fire (TNO method)ucƒ(qc, Apool, dpool, dAirm/s----
2.Default flame soot ratiofSr0.8 Fire/Explosion Event: Pool Fire; Pool Fire Model: Solid Surface---
3.Default maximum surface emissive powerSEPmax140 kW/m2Fire/Explosion Event: Pool Fire; Pool Fire Model: Solid Surface---
4.Flame height for pool fire (TNO method)Hfƒ(dpool, qc, Apool, dAir, u, ucm----
5.Flame soot ratio from the pool diameterfSrƒ(dpoolFire/Explosion Event: Pool Fire-5-
6.Flame tilt angle from Froude and Reynolds numbers (TNO method)fTAƒ(u, dpool°Pool Fire Model: Solid Surface---

Évaluation des risques

Risques naturels

Installations industrielles

Scientifique