Référence

TypeManual
TitreHAZUS-MH MR5 Technical Manual - Earthquake Model
AuteursFEMA
Année2010
ÉditeurU.S. Department of Homeland Security
Fichiers
NoFichierURLDate d'accès
1.PDF Document (4.28 MB)https://www.hsdl.org/?view&did=1275608/07/2021
AccèsPublic
Créé: Serkan GIRGIN, 13/09/2011 15:20:56 – Mis à jour: Amos NECCI, 08/07/2021 08:06:58

Classement des dommages

NoType d'unité d'installation industrielleNomDescription
1.Storage TankHAZUS (2010) - Storage Tank

Damage states for water storage tanks.

5
2.PumpHAZUS (2010) - Pump

Damage states for pumps at pumping plants and fuel facilities.

2
3.StackHAZUS (2010) - Stack

Damage states for stacks at oil refineries.

2
4.Storage TankHAZUS (2010) - Chemical Tank

Damage states for chemical tanks at water treatment plants.

3
5.BoilerHAZUS (2010) - Boiler

Damage states for boilers at generation facilities.

2
6.BuildingHAZUS (2010) - Building

Damage states for industrial buildings.

5

Courbes de fragilité

NoNomClassification des dommagesParamètreUnitéConditions de validité
1.HAZUS (2010) - Near Full, AnchoredHAZUS (2010) - Storage Tanklog μ̃PGAgBase Type: On-ground; Base Support Type: Anchored; Construction Material: Steel; Storage Condition: Atmospheric; Fill Percent: > 80 %v4-
2.HAZUS (2010) - Near Full, UnanchoredHAZUS (2010) - Storage Tanklog μ̃PGAgBase Type: On-ground; Base Support Type: Unanchored; Construction Material: Steel; Storage Condition: Atmospheric; Fill Percent: > 80 %v4-
3.HAZUS (2010) - Horizontal PumpHAZUS (2010) - Pumplog μ̃PGAgPosition: Horizontal1-
4.HAZUS (2010) - Vertical PumpHAZUS (2010) - Pumplog μ̃PGAgPosition: Vertical1-
5.HAZUS (2010) - Unanchored StackHAZUS (2010) - Stacklog μ̃PGAgBase Support Type: Unanchored1-
6.HAZUS (2010) - Anchored StackHAZUS (2010) - Stacklog μ̃PGAgBase Support Type: Anchored1-
7.HAZUS (2010) - Anchored Chemical TankHAZUS (2010) - Chemical Tanklog μ̃PGAgV: < 5 m3; Base Support Type: Anchored2-
8.HAZUS (2010) - Unanchored Chemical TankHAZUS (2010) - Chemical Tanklog μ̃PGAgV: < 5 m3; Base Support Type: Unanchored2-
9.HAZUS (2010) - Anchored BoilerHAZUS (2010) - Boilerlog μ̃PGAgBase Support Type: Anchored1-
10.HAZUS (2010) - Unanchored BoilerHAZUS (2010) - Boilerlog μ̃PGAgBase Support Type: Unanchored1-
11.HAZUS (2010)HAZUS (2010) - Buildinglog μ̃PGAg-4-

Natechs

NoDateRisqueInstallation
1.15/02/2017CUSTOM GUADALUPE, GuadeloupeCentrale thermique EDF Pointe Jarry-1

Évaluation des risques

Risques naturels

Installations industrielles

Scientifique