Natech | JX Nippon Oil & Energy Corp. - Sendai Refinery, Japan, Miyagi-Ken-Oki (Sendai) Earthquake, Japan, 12/06/1978 |
---|---|
Type d'unité d'installation industrielle | Storage Tank |
Classification des dommages | HAZUS (2010) - Storage Tank |
État des dommages | DS4 (Extensive) |
Endommagé | 3 |
Damage State (HAZUS, 2010) | Extensive |
Number of Damaged Units | 3 |
Références | Cooper, T. W., "A study of the performance of petroleum storage tanks during earthquakes, 1933-1995", 1997 |
Notes | Three large tanks failed, the oil over topped the containment dikes spilling into the refinery and into harbor waters. |
Accès | Public |
Évaluation des risques | Risques naturels | Installations industrielles | Scientifique | Utilisateurs |