Industrial Plant

NameRMP Validation Exercise Plant [Validation]
StatusOperational
CountryItaly
ProvinceVarese
CityIspra
EC8 Ground TypeType B
Ground Temperature285 K
NEHRP Site ClassVery dense soil and soft rock
Average Shear-Velocity (30m)360–760 m/s
Gravitational Acceleration9.8067 m/s2
TopographyUrban
Air Density1.1839 kg/m3
Partial vapor pressure of water in air1579 Pa
Solar Radiation0 W/m2
Ambient Temperature25°C
Ambient Pressure1 atm
Relative Humidity50%
Wind Speed2 m/s
Atmospheric StabilityStable
NACE CodeOther research and experimental development on natural sciences
AccessPublic
Created: Serkan GIRGIN, 2012/10/21 13:06:07 – Updated: Serkan GIRGIN, 2012/11/20 14:01:06

Plant Units

NoCodeTypeSubstanceProperties
1.U01Storage TankDiboraneStorage Condition: Pressure; Qstored: 2500 lb-
2.U03Storage TankChlorineStorage Condition: Refrigerated atmospheric; Qstored: 50000 lb; Adike: 275 ft2-
3.U04Storage TankAcrylonitrileQstored: 20000 lb-
4.U06Storage TankBromineStorage Condition: Atmospheric; Qstored: 20000 lb; hdike: 4 ft; Adike: 100 ft2-
5.U07Storage TankBromineStorage Condition: Atmospheric; Qstored: 20000 lb; Enclosure: Building; wfloor: 10 ft; lfloor: 10 ft-
6.U19Storage TankDiboraneTstorage: 25°C; Pstorage: 30 psi-
7.U21Storage TankAllyl alcoholStorage Condition: Atmospheric; Qstored: 20000 lb-
8.U16Storage TankPropaneStorage Condition: Pressure; Qstored: 50000 lb-
9.U14Storage TankEthylene oxideQstored: 10000 lb-
10.U20Storage TankHydrogen fluoride--
11.U22Storage TankBromine--
12.U24Storage TankChlorine--
13.U26Storage TankEthyleneTstorage: 9°C; Pstorage: 728 psi-
14.U28Storage TankEthyl etherQstored: 20000 lb-

On-site Hazard Data

NoHazardOn-site Hazard Parameters
1.RMP Validation Exercise Earthquake [Validation], Italy, 2012/10/21de: 50 km; EMS: Destructive; PGA: 0.8 g

Risk Assessments

NoHazard TypeNameDate# Plants
1.EarthquakeRMP Validation Exercise, Example 2 [Validation]2017/04/28 12:51:031

Serkan GIRGIN

2.EarthquakeRMP Validation Exercise, Example 3 [Validation]2017/04/28 12:51:031

Serkan GIRGIN

3.EarthquakeRMP Validation Exercise, Example 5 [Validation]2017/04/28 12:51:031

Serkan GIRGIN

4.EarthquakeRMP Validation Exercise, Example 6 [Validation]2017/04/28 12:51:031

Serkan GIRGIN

5.EarthquakeRMP Validation Exercise, Example 7 [Validation]2017/04/28 12:51:031

Serkan GIRGIN

6.EarthquakeRMP Validation Exercise, Example 9 [Validation]2017/04/28 12:51:031

Serkan GIRGIN

7.EarthquakeRMP Validation Exercise, Example 14 [Validation]2017/04/28 12:51:031

Serkan GIRGIN

8.EarthquakeRMP Validation Exercise, Example 16 [Validation]2017/04/28 12:51:031

Serkan GIRGIN

9.EarthquakeRMP Validation Exercise, Example 19 [Validation]2017/04/28 12:51:031

Serkan GIRGIN

10.EarthquakeRMP Validation Exercise, Example 4 [Validation]2017/04/28 12:51:031

Serkan GIRGIN

11.EarthquakeRMP Validation Exercise, Example 20 [Validation]2017/04/28 12:51:031

Serkan GIRGIN

12.EarthquakeRMP Validation Exercise, Example 21/23/25 [Validation]2017/04/28 12:51:031

Serkan GIRGIN

13.EarthquakeRMP Validation Exercise, Example 24 [Validation]2017/04/28 12:51:031

Serkan GIRGIN

14.EarthquakeRMP Validation Exercise, Example 22 [Validation]2017/04/28 12:51:031

Serkan GIRGIN

15.EarthquakeRMP Validation Exercise, Example 26 [Validation]2017/04/28 12:51:031

Serkan GIRGIN

16.EarthquakeRMP Validation Exercise, Example 1 [Validation]2012/11/23 05:18:211

Serkan GIRGIN

17.EarthquakeRMP Validation Exercise, Example 30 [Validation]2017/04/28 12:51:031

Serkan GIRGIN

18.EarthquakeRMP Validation Exercise, Example 29 [Validation]2017/04/28 12:51:031

Serkan GIRGIN

19.EarthquakeRMP Validation Exercise, Example 28 [Validation]2017/04/28 12:51:031

Serkan GIRGIN

Risk Assessment

Natural Hazards

Industrial Plants

Scientific

Users