Name | Duration of fireball |
---|---|
Property | Combustion Duration |
Type | Function |
Function |
|
Unit | s |
Validity Conditions | Fire/Explosion Event: BLEVE |
Precedence | Auto |
Disabled | No |
References | U.S. EPA, "Risk Management Program Guidance for Offsite Consequence Analysis", 1999 |
Notes | See U.S. EPA (1999), Equations D-31 and D-32 (section D.10, page D-22) |
Access | Public |
Risk Assessment | Natural Hazards | Industrial Plants | Scientific | Users |