Property Estimator

NameRMP reference table for ammonia
PropertyRMP Reference Table
TypeFunction
Function
if ([!substance_cas_no] == '7664-41-7') {
  if ([AS] == 'F') return '10';
  if ([AS] == 'D') return '23';
}
Validity ConditionsStorage Condition:  Pressure,  Gas liquefied under pressure
Precedence2
DisabledNo
ReferencesU.S. EPA, "Risk Management Program Guidance for Offsite Consequence Analysis", 1999
AccessPublic
Created: Serkan GIRGIN, 2012/08/17 12:07:27 – Updated: Amos NECCI, 2021/12/02 16:03:39

Risk Assessment

Natural Hazards

Industrial Plants

Scientific

Users