Property Estimator

NameRelease rate from a hole for chocked flow (gas)
PropertyRelease Rate
TypeFunction
Function
[Cd]*[Ah:m2]*sqrt([HR]*[PST:Pa]*[d:kg/m3]*pow(2/([HR]+1), ([HR]+1)/([HR]-1)))
Unitkg/s
Validity ConditionsReleased Quantity: 
PrecedenceAuto
DisabledNo
ReferencesU.S. EPA, "Risk Management Program Guidance for Offsite Consequence Analysis", 1999
Notes

See U.S. EPA (1999), Equation D-8 (section D.6, page D-14)

AccessPublic
Created: Serkan GIRGIN, 2012/09/10 16:21:03

Risk Assessment

Natural Hazards

Industrial Plants

Scientific