Name | Default Radiation Intensity from fireball's Combustion Duration and Thermal Dose. |
---|---|
Property | Endpoint Radiation Intensity |
Type | Function |
Function |
|
Unit | W/m2 |
Validity Conditions | Fire/Explosion Event: BLEVE |
Precedence | Auto |
Disabled | No |
References | U.S. EPA, "Risk Management Program Guidance for Offsite Consequence Analysis", 1999 |
Notes | See U.S. EPA (1999), Equation D-34 (section D.10, page D-23) |
Access | Public |
Risk Assessment | Natural Hazards | Industrial Plants | Scientific | Users |