Referans

TürArticle
BaşlıkSeismic risk of atmospheric storage tanks in the framework of quantitative risk analysis
YazarlarSalzano, E.; Iervolino, I.; Fabbrocino, G.
DergiJournal of Loss Prevention in the Process Industries
Yıl2003
Cilt16
Sayı5
Sayfalar403-409
Özet

The quantitative risk assessment of industrial plants is based on integrated procedures to quantify human, environmental and economical losses related to relevant accidents. Accordingly, seismic risk analysis has to be integrated in order to obtain reliable results.

In this work, some considerations regarding the intensity and probability of occurrence of earthquakes and the vulnerability of atmospheric storage tanks subjected to seismic actions are given.

Structural vulnerability based on observational data has been processed in the form of "probit analysis", a simple and useful statistic tool. Suggestions concerning industrial seismic-related accidental scenarios are also given.

Dosyalar
NoDosyaURLErişim Tarihi
1.PDF Document (131.49 KB)http://wpage.unina.it/iuniervo/papers/Salzano_et_al_JLP.pdf06/05/2014
ErişimGenel
Yaratılma: Serkan GIRGIN, 13/09/2011 15:16:26 – Güncelleme: Serkan GIRGIN, 06/05/2014 15:17:39

Kırılganlık Eğrileri

NoAdHasar SınıflandırmasıParametreBirimGeçerlilik Koşulları
1.HAZUS (2010) - Near Full, AnchoredHAZUS (2010) - Storage TankPGAgBase Type: On-ground; Base Support Type: Anchored; Construction Material: Steel; Storage Condition: Atmospheric; Fill Percent: > 80 %vlog μ̃4-
2.HAZUS (2010) - Near Full, UnanchoredHAZUS (2010) - Storage TankPGAgBase Type: On-ground; Base Support Type: Unanchored; Construction Material: Steel; Storage Condition: Atmospheric; Fill Percent: > 80 %vlog μ̃4-
3.Eidinger et al. (2001) - Fill ≥ 50%, AnchoredHAZUS (2010) - Storage TankPGAgBase Type: On-ground; Base Support Type: Anchored; Construction Material: Steel; Storage Condition: Atmospheric; Fill Percent: > 50 %vlog μ̃41
4.Eidinger et al. (2001) - Fill ≥ 50%, UnanchoredHAZUS (2010) - Storage TankPGAgBase Type: On-ground; Base Support Type: Unanchored; Construction Material: Steel; Storage Condition: Atmospheric; Fill Percent: > 50 %vlog μ̃41
5.Eidinger et al. (2001) - Fill ≥ 50%HAZUS (2010) - Storage TankPGAgBase Type: On-ground; Construction Material: Steel; Storage Condition: Atmospheric; Fill Percent: > 50 %vlog μ̃42
6.Eidinger et al. (2001)HAZUS (2010) - Storage TankPGAgBase Type: On-ground; Construction Material: Steel; Storage Condition: Atmosphericlog μ̃4-