Classification des dommages

NomMoschonas et al. (2014) - Spherical Pressure Vessels
Type de risqueEarthquake
Type d'unité d'installation industrielleStorage Tank
Description

Damage states for spherical pressure vessels according to Moschonas et al. (2014).

Etats
NoCodeNomDescription
1.DS0No Damage

No damage.

2.DS1Minor Damage

Minor yields that correspond to minor permanent deformations at critical sections of a small percentage of columns and/or braces.

3.DS2Moderate Damage

For class 1 sections according to EC3, moderate yields corresponding to moderate permanent deformations at critical sections of a moderate percentage of columns and/or braces without any global buckling failure of columns.

For class 2 and 3 sections according to EC3, minor-to-moderate yields that correspond to minor-to-moderate permanent deformations at critical sections of a moderate percentage of columns and/or braces without any local buckling at critical sections of columns.

4.DS3Major Damage

For class 1 sections according to EC3, major yields causing major permanent deformations at critical sections of a large percentage of columns and/or braces with global buckling failure of columns where maximum compression occurs.

For class 2 and 3 sections according to EC3, minor-to-major yields that cause minor-to-major permanent deformations at critical sections of a large percentage of columns and/or braces with local buckling of critical sections at the columns where maximum compression occurs.

5.DS4Collapse

Buckling failure with subsequent collapse of the pressure vessel.

RéférencesI. Moschonas; C. Karakostas; V. Lekidis; S. Papadopoulos, "Investigation of seismic vulnerability of industrial pressure vessels", 2014
AccèsPublic
Créé: Serkan GIRGIN, 12/05/2016 15:48:28 – Mis à jour: Serkan GIRGIN, 20/05/2016 16:20:22

États à risque

NoÉtat des dommagesParamètres du scénarioConditions de validité
1.DS0 (No Damage)LOC State: None--
2.DS1 (Minor Damage)LOC State: Minor--
3.DS2 (Moderate Damage)LOC State: Moderate--
4.DS3 (Major Damage)LOC State: Major--
5.DS4 (Collapse)LOC State: Catastrophic--

Courbes de fragilité

NoNomParamètreUnitéConditions de validité
1.Moschonas et al. (2014), Non-braced Spherical Pressure VesselPGAgShape: Spherical; Storage Condition: Pressure, Gas liquefied under pressure, Gas under pressurelog μ̃4-
2.Moschonas et al. (2014), Braced Spherical Pressure VesselPGAgShape: Spherical; Column Support Type: Diagonal Braces; Storage Condition: Pressure, Gas liquefied under pressure, Gas under pressurelog μ̃4-

Évaluation des risques

Risques naturels

Installations industrielles

Scientifique

Utilisateurs