| Ad | Fill Percent |
|---|---|
| Kod | FL |
| Açıklama | Filling level of the storage unit. It is common for oil tanks to be less than completely full. It is uncommon for water tanks to be less than 80% full; most water tanks are kept between 80% to 100% full, depending on time of day (Eidinger et al., 2001, Part 2, p. 79). |
| Tür | Storage (Tesis Ünitesi) |
| Veri Türü | Sayısal |
| Birim | %v |
| Gösterim Sırası | 10 |
| Mesajı giriniz. | Please enter a fill level. |
| Geçersiz Mesajı | Invalid fill level. |
| Doğrulama Kuralı | |
| Erişim | Genel |
| No | Ad | Değer | Geçerlilik Koşulları | |||
|---|---|---|---|---|---|---|
| 1. | Default fill percent | 100 %v | - | - | - | - |
| 2. | Default fill percent | 80 %v | tcontainer: IBC, Drums | - | 5 | - |
| 3. | Default fill percent (gas) | 100 %v | Storage Condition: Gas under pressure | - | 1 | - |
| 4. | Default fill percent (liquid) | 85 %v | Storage Condition: Atmospheric, Refrigerated atmospheric, Pressure, Refrigerated pressure | - | 1 | - |
| 5. | Fill percent from storage volume and stored volume | ƒ(Vstored, Vstorage) %v | - | - | 2 | - |
Risk Değerlendirmesi | Doğal Afetler | Endüstriyel Tesisler | Bilimsel | Kullanıcılar |