Name | Release Duration |
---|---|
Code | tr |
Symbol | t<sub>release</sub> |
Type | Release (Plant Unit) |
Data Type | Numeric |
Unit | min |
View Order | 4 |
Please enter a message. | Please enter a release duration. |
Invalid Message | Invalid release duration. |
Validation Rule |
|
Access | Public |
No | Name | Value | Validity Conditions | |||
---|---|---|---|---|---|---|
1. | Release duration for catastrophic release | 1 s | LOC State: Catastrophic | - | - | - |
2. | Release duration for major release | 30 min | LOC State: Major | - | - | - |
3. | Release duration for minor release | 10 min | LOC State: Minor | - | - | - |
4. | Release duration for moderate release | 10 min | LOC State: Moderate | - | - | - |
5. | Release duration from released quantity and relase rate | ƒ(Qreleased, qrelease) min | - | - | - | - |
6. | Release duration from stored quantity above hole and release rate | ƒ(Qstored, hole, qrelease) min | - | - | - | - |
7. | RMP Worst-case scenario release duration for gaseous substances | 10 min | Substance Type: Toxic; LOC State: ∅; Release State: Gas; RMP Scenario: Worst-case | - | - | - |
Risk Assessment | Natural Hazards | Industrial Plants | Scientific | Users |