Reference

TypeReport
TitleMethods for the Calculation of the Physical Effects of the Escape of Dangerous Material (Liquids and Gases)
AuthorsTNO
Year1980
InstitutionTNO Bureau for Industrial Safety
PublisherNetherlands Organization for Applied Scientific Research
AccessPublic
Created: Serkan GIRGIN, 2012/11/19 14:28:06

Property Estimators

NoNamePropertyValueValidity Conditions
1.Characteristic wind speed for pool fire (TNO method)ucƒ(qc, Apool, dpool, dAirm/s----
2.Default flame soot ratiofSr0.8 Fire/Explosion Event: Pool Fire; Pool Fire Model: Solid Surface---
3.Default maximum surface emissive powerSEPmax140 kW/m2Fire/Explosion Event: Pool Fire; Pool Fire Model: Solid Surface---
4.Flame height for pool fire (TNO method)Hfƒ(dpool, qc, Apool, dAir, u, ucm----
5.Flame soot ratio from the pool diameterfSrƒ(dpoolFire/Explosion Event: Pool Fire-5-
6.Flame tilt angle from Froude and Reynolds numbers (TNO method)fTAƒ(u, dpool°Pool Fire Model: Solid Surface---

Risk Assessment

Natural Hazards

Industrial Plants

Scientific

Users