| Name | Conditional explosion probability for flammable gases (Cox et al., 1990) |
|---|---|
| Property | Conditional Explosion Probability |
| Type | Value |
| Value | 4 |
| Unit | % |
| Validity Conditions | Substance Type: Flammable; Gaseous Release Rate: < 1 kg/s; Fire/Explosion Event: Vapor Cloud Explosion |
| Precedence | Auto |
| Disabled | No |
| References | A. W. Cox; F. P. Lees; M. L. Ang, "Classification of Hazardous Locations", 1990 |
| Notes | See Table 16.75 in Lees (2012). |
| Access | Public |