Name | Critical buckling pressure from vessel capacity |
---|---|
Property | Critical Buckling Pressure |
Type | Function |
Function |
|
Unit | Pa |
Validity Conditions | Storage Condition: Atmospheric; Damage State (Flood): Shell Buckling |
Precedence | Auto |
Disabled | No |
References | Gabriele Landucci; Giacomo Antonioni; Alessandro Tugnoli; Valerio Cozzani, "Release of hazardous substances in flood events: Damage model for atmospheric storage tanks", 2012 |
Notes | Provides a simplified conservative estimation of the vessel resistance from an envelope correlation of critical buckling pressure with respect to vessel capacity C. See Section 2.5 in the article for details. |
Access | Public |
Risk Assessment | Natural Hazards | Industrial Plants | Scientific | Users |