| Industrial Plant | RMP Validation Exercise Plant [Validation], Italy |
|---|---|
| Type | Storage Tank |
| Code | U14 |
| Substance | Ethylene oxide (75-21-8) |
| Tank height from the ground | 0 m |
| Volume | 6.0465 m3 |
| Surface Roughness | 700 mm (0.7 m) |
| Obstruction Class | Obstructed |
| Status | Operational |
| Shell Density | 7800 kg/m3 |
| Base Type | On-ground |
| Base Support Type | Anchored |
| Construction Material | Steel |
| Storage Volume | 6.0465 m3 |
| Storage Capacity | 5336.4 kg |
| Storage Condition | Pressure |
| Storage Temperature | 25°C |
| Storage Pressure | 1.7284 atm |
| Gauge Pressure | 0.7284 atm |
| Storage State | Liquid |
| Fill Percent | 85 %v |
| Stored Volume | 5.1395 m3 |
| Stored Quantity | 10000 lb (4535.9 kg) |
| Passive Release Mitigation Factor | 1 |
| Active Release Mitigation Factor | 1 |
| Notes | See U.S. EPA (1999), Example 14 (Chapter 4, page 4-6). |
| Access | Public |
| No | Hazard Type | Name | Date | # Plants | ||
|---|---|---|---|---|---|---|
| 1. | Earthquake | RMP Validation Exercise, Example 14 [Validation] | 2017/04/28 12:51:03 | 1 | Serkan GIRGIN |
Risk Assessment | Natural Hazards | Industrial Plants | Scientific | Users |