Plant Unit

Industrial PlantRMP Validation Exercise Plant [Validation], Italy
TypeStorage Tank
CodeU26
SubstanceEthylene (74-85-1)
Tank height from the ground0 m
Surface Roughness700 mm (0.7 m)
Obstruction ClassObstructed
StatusOperational
Shell Density7800 kg/m3
Base TypeOn-ground
Base Support TypeAnchored
Construction MaterialSteel
Storage ConditionRefrigerated pressure
Storage Temperature9°C
Storage Pressure728 psi (49.537 atm)
Gauge Pressure48.537 atm
Storage StateLiquid
Fill Percent85 %v
Passive Release Mitigation Factor
Active Release Mitigation Factor
Notes

See U.S. EPA (1999), Example 26 (section 9.1, page 9-1).

AccessPublic
Created: Serkan GIRGIN, 2012/11/22 15:02:03

Risk Assessments

NoHazard TypeNameDate# Plants
1.EarthquakeRMP Validation Exercise, Example 26 [Validation]2017/04/28 12:51:031

Serkan GIRGIN

Risk Assessment

Natural Hazards

Industrial Plants

Scientific

Users