NameRMP Validation Exercise, Example 24 [Validation]
Date2017/04/28 12:51:03
HazardRMP Validation Exercise Earthquake [Validation], 2012/10/21
Industrial PlantRMP Validation Exercise Plant [Validation], Italy
Plant UnitStorage Tank, U24, Chlorine (7782-50-5)
Damage ClassificationHAZUS (2010) - Storage Tank
Fragility CurveAuto
Flexible fragility curve selectionYes
Evaluate compatible plant units onlyNo
Use private property estimatorsNo
TopographyUrban
Release Rate500 lb/min (226.8 kg/min)
RMP ScenarioAlternative
Notes

Risk Management Program Guidance for Offsite Consequence Analysis (U.S. EPA, 1999), Example 24 (Chapter 8, page 8-5).

AccessPublic
1. RMP Validation Exercise Plant [Validation], Italy
NoPlant UnitHazard ParametersFragility CurveDamage EstimateScenario ParametersEnd-point Distance
1.Storage Tank (U24)
Chlorine, Base Type: On-ground 
PGA: 0.8 g AR-IAP-120DS2: P(0.9917)Qreleased: 0 kg 643.74 m, P(0.9917)
DS3: P(0.8648)fV, involved: 10 %v 643.74 m, P(0.2594)
DS4: P(0.5858)fV, involved100 %v 643.74 m, P(0.2929)
DS5: P(0.403)fV, involved100 %v 643.74 m, P(0.403)
Created: Serkan GIRGIN, 2012/11/22 13:47:18